Description
Benchtop Spectrophotometer YR05476 is a state-of-the-art instrument designed by Kalstein for precise color measurement and analysis. With a 7-inch TFT capacitive touch screen, this compact spectrophotometer offers an intuitive interface, making it ideal for laboratory and research and development environments. It boasts reflective d/8 and transmissive d/0 geometries, ensuring accurate color evaluations for both solids and liquids. Its powerful PC software and extensive data storage capabilities allow researchers to streamline their color analysis workflows, making it a preferred choice in industries such as plastics, paint, textiles, and more.
Market Price
The Benchtop Spectrophotometer YR05476 is positioned in a competitive market where precision and reliability are paramount. The price for this spectrophotometer generally ranges from around 14,000 USD to 14,800 USD, reflecting its advanced features and high-quality components. For an exact pricing, you can request a quote directly from us or explore our Kalstein Plus platform for automatic quotations tailored to your needs.
Frequently Asked Questions
What industries can benefit from using the YR05476 spectrophotometer? This instrument is extremely versatile and can be applied in fields such as plastics, electronics, paint and ink, printing, textiles, garments, leather, and more, providing reliable color analysis and quality control.
What is the warranty period for this product? The spectrophotometer comes with a standard warranty covering five years or over three million measurements, ensuring longevity and reliability in its performance.
Advantages and Disadvantages
The Benchtop Spectrophotometer YR05476 offers several advantages, including high accuracy, large data storage, and user-friendly operation. Its advanced optical geometry and wide wavelength range ensure precise color analysis. However, one potential drawback could be its higher price point compared to less sophisticated models, which might not meet all budget constraints.
Product Usage in the Field
In practical applications, the YR05476 spectrophotometer is used for measuring the color and appearance of diverse materials such as powders, liquids, and pastes in laboratory settings. Its ability to switch between multiple measurement modes makes it adaptable for quality assurance processes in manufacturing and research environments.
Recommendations
For optimal performance, users should regularly calibrate the spectrophotometer using standard calibration boards. Keeping the device in controlled temperature environments and utilizing the built-in temperature sensor will help maintain measurement precision over time. Consult the user guide for additional maintenance tips and best practices.
Features
- High configuration of hardware: 7-inch TFT Color Capacitive Touch-screen Display, Bluetooth 2.1, Concave Grating.
- Double Array 256 Image Element CMOS Sensor, Long lifespan LED, UV LED, and xenon lamp.
- Accurate Lab value for precise color transmission.
- Automatic measuring aperture identification, customizable apertures.
- Built-in temperature sensor for measurement precision.
- Wavelength range of 360nm – 780nm for professional UV measurement.
- Independently monitored light source for reliability.
- Multiple measurement modes for diverse user requirements.
- Extensive data storage for up to 40,000 test results.
- Powerful PC software with extended functions.
Technical Specifications
Model | YR05476 |
Optical Geometry | Reflect: di:8°, de:8° (diffused illumination, 8-degree viewing angle) SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source; Haze (ASTM D1003), Conforms to CIE No.15,GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
Integrating Sphere Size | Φ154mm |
Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source, 420nm Cut-off light source |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | Reflective: Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
Transmissive: Φ30mm/Φ25mm; | |
Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
Color Space | CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN Lab99 |
Color Difference Formula | ΔE * ab, ΔE * uv, ΔE * 94, ΔE * cmc(2:1), ΔE * cmc(1:1), ΔE * 00, DINΔE 99, ΔE (Hunter), |
Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), |
YI (ASTM D1925, ASTM 313), | |
MI (Metamerism Index), | |
Staining Fastness, Color Fastness, Color Strength, Opacity, | |
8° Glossiness, Gardner Index, Pt-Co Index, 555 Index, Haze (ASTM D1003) | |
Observer Angle | 2°/10° |
Illuminant | D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%) |
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) | |
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.12 |
(Average for 12 BCRA Series II color tiles) | |
Dimension | L*W*H=370x300x200mm |
Weight | Approx. 9.6kg |
Power | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB & Bluetooth & Print serial port |
Data Storage | Standard 5000 Pcs, Sample 40000 Pcs |
Language | Simplified Chinese, Traditional Chinese, English, (Optional Customized German, French and Spanish) |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber, Transmissive Test Component |
Optional Accessory | Micro-printer, Micro Aperture (4mm) transmission test clamp component, Instrument inversion components |
Notes: | The specifications are subject to change without notice. |